AR-B104D Software Programming Guide
19
2.3.31 SetPGCycle
Description
Set the pulse generator cycles of the selected output channel.
Syntax
XXX_SetPGCycle (i16 CardNum, i16 ChannelNum, u16 Cycle)
Argument
CardNum: The card number of AR-B104D. Range from 1~4.
ChannelNum: Output channel number. Range from 0~11.
Cycle: The number of the related pulse generator running cycle.
2.3.32 GetPGCycle
Description
Get the pulse generator cycles of the selected output channel.
Syntax
XXX_GetPGCycle (i16 CardNum, i16 ChannelNum, u16* Cycle)
Argument
CardNum: The card number of AR-B104D. Range from 1~4.
ChannelNum: Output channel number. Range from 0~11.
Cycle: The memory address of buffer to put the number of the related
pulse generator running cycle.
2.3.33 SetPG
Description
Set all pulse generator parameters of the selected output channel and
immediately start the pulse generator.
Syntax
XXX_SetPG (i16 CardNum, i16 ChannelNum, u8 Base, u8 High, u8 Low,
u16 Cycle)
Argument
CardNum: The card number of AR-B104D. Range from 1~4.
ChannelNum: Output channel number. Range from 0~11.
Base: The pulse generator timebase of the selected output channel. 0
indicates the base is 1 ms; 1 indicates the base is 100 ms.
High: The time of the related pulse generator remains high in one
cycle.
Vista de página 22